1. Fault phenomenon: the temperature display is different from the set temperature
Cause analysis: insufficient steam pressure; steam sensor failure; electric heating heating failure; temperature sensor
Fault; the damper of the moisture exhaust duct is too large.
Remedy: check and repair the steam source; replace the sensor; check and repair the electric heater; replace the sensor;
Adjust the damper.
2. Fault phenomenon: the fuselage moves laterally
Reason analysis: the eccentric block of the vibration motor is not synchronized
Remedy: Adjust the eccentric block
3. Fault phenomenon: the discharge speed is too fast
Reason analysis: the air volume at the feed end is too large; the included angle of the eccentric block of the vibration motor is too small
Remedy: Adjust the air regulating plate and the eccentric block
4. Fault phenomenon: the discharge speed is too slow
Reason analysis: the air volume at the discharge end is too large; the included angle of the eccentric block of the vibration motor is too large
Remedy: Adjust the eccentric block and the air inlet plate
5. Fault phenomenon: there are large particles at the discharge port of the cyclone dust collector
Cause analysis: the air intake is too large; the air volume of the induced draft fan is too large
Remedy: Adjust the air inlet plate and the air induction plate